Skip to main content

🚿 Warm water and shower - Camper Castle (Bürstner Limited T)

Here are all the steps to take for a warm shower in your Camper Castle:

Hot Water

  • To use hot water, open the gas bottle.
  • Don't forget to open the gas flow in the kitchen by turning the left grey lever vertically:

  • Check if the water level is sufficient. For a thorough shower, we recommend a fill level of 50%.
  • The boiler must be filled with water. To do this, turn on the water pump, let the water run briefly, and turn the tap to hot.

Then turn on the boiler with these steps on the Truma display:

  1. Turn the black button clockwise until you see the symbol with a thermometer under water blinking:
  2. Click on the black button to confirm.
  3. The text "OFF" will appear. Turn the wheel clockwise to select select the mode: ECO (40℃), HOT (60℃) or BOOST
  4. Once you find the desired mode, press the button to select.
  5. The main menu will appear again and the boiler should be working.
  6. You can also operate your Truma via a gas/electricity mix or pure electricity.
  7. Select the gas cylinder/flash symbol:
    gas und strom truma.jpg
    GAS= LP(gas)
    MIX 1= LP(gas) + 850W
    MIX 2= LP(gas) + 1700W
    EL 1= 850W
    EL 2= 1700W
  8. To use "MIX" or "EL", make sure that you are either connected to the external power supply or (if available) the generator is in operation.
  9. Wait about 20 minutes until the boiler is hot.

Click here to go directly to the explanation video:

Indoor Shower

To prepare the shower, carefully pull the magnetic wall with the sink to the other side and use the built-in shower curtain to prevent the inside of the door from getting wet:

Troubleshooting

If an error occurs or the water does not get warm, try the following:

  • Check if gas is flowing in general.
  • Make sure the shut-off valve for the boiler (see above) is open.
  • If you forgot to open the gas bottle or the shut-off valve before turning it on at the control panel, this error must be cleared on the Truma control unit:

Common errors on the Truma display:

E517H // E507H // E516H: The error code appears when the gas supply is interrupted. Turn off the system, turn on the gas, press the black button to confirm that the error has been acknowledged. You may need to reset the appliance and start the process again.

W412H: The error appears when a window is open. This activates the safety pin to prevent exhaust gases from the heater entering the vehicle interior. To allow the exhaust gases to flow again, close the window.

W418H // W411H // W303H // E654H // E566H: The error code appears if the voltage of the camping battery is insufficient.
Check the battery capacity on your on-board display. If the value is below 12.3 V (50%), the battery must be charged before starting the heater.
Repeated unsuccessful restarts of the Truma unit can cause the heater to block.

If another error code is displayed, please contact us so that we can help you further.

Reset:

You found the cause of the error and fixed it? Great! Some errors disappear by themselves.
Others need to be confirmed by navigating to the black button to the exclamation mark (by turning the black button):
truma.jpg

Now press the black button to confirm the error. The symbol should now disappear and the heater can be put back into operation using the familiar steps.

Resetting the Truma unit after an error/warning message. Only ONCE!!!

In some cases, it helps to manually reset the Truma. Try this only once – if you repeatedly reset it without eliminating the cause, the entire system can be permanently disabled.

 

Was this article helpful?
4 out of 14 found this helpful

Articles in this section

See more